Event
No.
Source
ID
HFWRAS_SYS
12
525
HFWRAS_SYS
13
539
HFWRAS_SYS
14
540
HFWRAS_SYS
15
541
HFWRAS_APP
16
769
HFWRAS_APP
17
771
HFWRAS_SYS
18
800
HFWRAS_SYS
19
900
HFWRAS_SYS
20
2001
HFWRAS_SYS
21
2002
HFWRAS_SYS
22
2003
HFWRAS_SYS
23
2004
HFWRAS_SYS
24
2009
Table 9-3 Event log entries unique to the equipment (2/3)
Type
Information
In DIMM%1, error
corrections have been
occurring at a high
frequency.
Error
The %1 monitor finished.
Information
In DIMM%1, the number
of single-bit errors that
have been corrected since
the OS started is %2
(comparison with last
time: %3).
Warning
DIMM%1 might have
failed.
Error
An error occurred in %1.
Error code = %2.
Error
Because an incorrect value
is specified in the registry
value %1, the default
value %2 is set.
Information
%1
Detailed code = %2.
Information
The power shutdown factor
code is %1.
Error
The drive in drive bay %1
is offline because of a
failure.
Information
The RAID status is
optimal.
Error
RAS could not acquire the
RAID status. The RAID
status is unknown.
Information
The RAID status was
revealed.
Information
The drive in drive bay %1
is offline because of
manual operation.
Description
The DIMM might have failed. Contact
your system administrator or
maintenance personnel.
Hardware monitoring of the RAS
software has been terminated. If
restarting the equipment does not
resolve the error, contact the system
administrator or maintenance personnel.
No action required.
The DIMM might have failed. Contact
the system administrator or maintenance
personnel.
An error was generated by the RAS
software while the software was
running. If restarting the equipment does
not resolve the error, contact the system
administrator or maintenance personnel.
If restarting the equipment does not
resolve the error, contact the system
administrator or maintenance personnel.
A STOP error occurred. Check the error
and contact the system administrator or
maintenance personnel.
A power shutdown occurred. Contact
the system administrator or maintenance
personnel.
Read the description of abnormal
temperature in 10.4.2 and take action
accordingly.
No action required.
Contact the system administrator or
maintenance personnel.
No action required.
No action required.