4.
Step 2 Fix the DC power cable connector to the PWR port, as shown in
positive and negative polarities are correct during the installation.
Figure 6-121 Installing the round connector
Issue 03 (2019-04-01)
Tightly bind the PVC tape at the ends of the wrapping section, and cut off excessive
cable ties.
NOTE
After a cable tie is tightly bound, cut the tie at a distance if 3 mm to 5 mm from the clip in outdoor
scenarios and directly cut the tie at the clip in indoor scenarios.