5. SEQUENCE PROGRAMS AND SFC PROGRAMS
[Operation Timing]
[Data Settings]
Downloaded from
ManualsNet.com
Execution command
DSFLP instruction
Start accept flag
(1) Setting the axis for which the current value change is to be executed
The axis for which the current value change set in (D) is executed is set as
follows.
D
Example
The started axis is designated as follows.
• Axis 1 ......................................................................D1
• Interpolation control with axis 1 and axis 2 .............D1 or D2
(2) Current value change
The setting for a current value change is as follows.
• Current value change.............Set K0 or H0.
POINT
When using a DSFLP instruction, it is not possible to indirectly designate (D)
or n using index registers (Z, V).
If an indirect designation with an index register is made, an operation error
occurs, and the DSFLP instruction is not executed.
search engine
ON
OFF
Started axis No.
⋅ The relevant axis No. can be set in the range 1 to 4 or 1 to8.
⋅ Set the interpolation control time for one of the axes controlled in
interpolation.
Device symbol (only D can be set)
DSFLP
D0Z
5 − 9
Current value change completion
K1
Indirect designation using index register