Mitsubishi Electric SV13/22 Programming Manual page 312

Table of Contents

Advertisement

8. AUXILIARY AND APPLIED FUNCTIONS
Downloaded from
ManualsNet.com
POINTS
(1) The address setting range for absolute position system is −2147483648
to 2147483647.
It is not possible to restore position commands that exceed this limit, or
current values, after a power interruption.
When performing an infinite feed operation, solve this problem by setting
the units to degrees or by setting a rotary table (when using SV22).
(2) Even when the current value address is changed by a current value
change instruction, the restored data for the current value after a power
interruption is the value based on the status prior to execution of the
current value change instruction.
(3) When zeroing has not been completed, restoration of the current value
after a power interruption is not possible.
search engine
8 − 14

Advertisement

Table of Contents
loading

This manual is also suitable for:

A172shcpunA171shcpun

Table of Contents