7. POSITIONING CONTROL
[Program Example]
Downloaded from
ManualsNet.com
(3) If travel value under position control is less than deceleration distance
(a) If the position control travel value is less than the deceleration distance at
the controlled speed, deceleration processing starts immediately when
CHANGE is input.
(b) The difference between travel value for the deceleration stop and position
control is the overrun. If an overrun occurs, the error detection signal
(M1607+20n) turns ON and error code 209 is stored in the data register.
(c) The positioning completed signal (M1601+20n) does not turn ON.
Speed/position switching
enable signal (M1805+20n)
Speed/position switching
input (CHANGE)
Error detection (M1607 20n)
Positioning completed signal
(M1601 20n)
+
(4) Stroke limit check
No stroke limit range check is made during the speed mode. If the travel value
exceeds the stroke limit range, a minor error (error code: 210) occurs when
position mode is selected, and a deceleration stop occurs.
(5) Switching time from speed control to position control
Switching from speed control to position control takes 1 ms after the external
CHANGE signal turns ON.
This program executes speed/position switching control under the conditions
below.
(1) System configuration
Speed/position switching control of Axis 4.
A172SHCPUN
A172B
search engine
V
OFF
OFF
OFF
+
OFF
A172S
A1S
ENC
X10
Start command
(X000)
CHANGE signal
MR-[]-B
MR-[]-B
MR-[]-B
MR-[]-B
Axis
Axis
Axis
Axis
1
2
3
4
M
M
M
M
7 − 71
Travel value under
position control
Overrun
t
ON
ON
ON

Advertisement