Mitsubishi Electric SV13/22 Programming Manual page 347

Table of Contents

Advertisement

APPENDICES
Number
(Note-
M9025
Clock data set request
1)
M9026
Clock data error
(Note-
M9028
Clock data read request
2)
M9030
0.1 second clock
M9031
0.2 second clock
M9032
1 second clock
M9033
2 second clock
M9034
1 minute clock
M9036
Always ON
M9037
Always OFF
ON for 1 scan only after
M9038
RUN
RUN flag (OFF for 1 scan
M9039
only after RUN)
M9040
PAUSE enable coil
M9041
PAUSE status contact
M9042
STOP status contact
Sampling trace
M9043
completed
M9046
Sampling trace
Sampling trace
M9047
preparation
Number of output
M9049
characters selection
(Note-
M9052
SEG instruction switch
2)
(Note-
M9053
EI/DI instruction switch
2)
Downloaded from
ManualsNet.com
Table 3.1 Special Relay List (Continued)
Name
Stored Data
OFF No processing
ON
Data set request
OFF No error
ON
Error
OFF No processing
ON
Read request
0.05
0.05
SEC.
SEC.
0.1
0.1
SEC.
SEC.
0.5
0.5
SEC.
SEC.
1 SEC.
1 SEC.
30 SEC.
30 SEC.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF PAUSE disable
ON
PAUSE enabled
OFF PAUSE not in effect
ON
PAUSE in effect
OFF STOP not in effect
ON
STOP in effect
OFF Sampling trace in progress
ON
Sampling trace completed
OFF Trace not in progress
ON
Trace in progress
OFF Sampling trace stop
ON
Sampling trace start
OFF Output until NULL code
ON
16 characters output
OFF 7-segment display
ON
I/O part refresh
OFF Sequence interrupt control
ON
Link interrupt control
search engine
!
Writes the clock data stored in D9025 to D9028 to the clock devices
after execution of the END instruction in the scan in which M9025 is
switched ON.
!
Comes ON when there is an error in he clock data (D9025 to D9028)
values. OFF when there is no error.
!
When M2098 is ON, the clock data is read to D9025 to D9028 as
BCD data.
!
These relays generate the 0.1 second, 0.2 second, 1 second, 2
second, and 1 minute clocks.
!
These relays do not go ON/OFF with each scan but when their
respective fixed intervals have elapsed, even during a scan.
!
These relays start from the OFF status when the power is turned on
or resetting.
!
Relay used for initialization during a sequence program or as a
dummy contact for an application instruction.
!
M9036 and M9037 retain their ON or OFF status regardless of the
settings of the key switch on the front of the CPU, but M9038 and
M9039 change in accordance with the key switch status. They go
OFF when the key switch is set to the STOP position.
1 scan
When the key switch is at a position other than STOP, M9038 comes
ON for one scan only, and M9039 goes OFF for one scan only.
1 scan
!
When the RUN/STOP key switch is set to PAUSE or the remote
PAUSE contact is turned on, provided M9040 is ON, the PAUSE
status is established and M9041 comes ON.
!
ON when the RUN/STOP key switch is set to STOP.
!
Comes ON on completion of the number of sampling traces set in the
parameters are completed after execution of the STRA instruction.
After that, it is reset by execution of the STRAR instruction.
!
ON during execution of a sampling trace
!
A sampling trace cannot be executed unless M9047 has been turned
ON.
When M9047 is turned OFF, the sampling trace is stopped.
!
When M9049 is OFF, output continues until the NULL (00H) code.
When M9049 is ON, ASCII code for 16 characters is output.
!
When M9052 is ON it is executed as the I/O partial refresh
instruction. When M9052 is ON, it is executed as the 7-segment display
instruction.
!
Turn ON when a link refresh enable/disable (EI, DI) instruction is
executed.
APP − 29