4-6-7 On-the-fly marking: Multiple triggers
SHUTTER OPEN OUT
(No.39)
READY OUT (Y5)
TRIGGER IN (X5)
PROCESSING OUT (Y10)
LASING OUT (No.40)
PROCESSING END OUT
(Y11)
*1 : When trigger mode is set to Multiple triggers at on-the-fly marking, max. 16 triggers can be accepted while
PROCESSING OUT (Y10) is ON.
Item
Time
T1
―
T2
2ms or more
T3
―
T4
―
T5
2 to 510ms
• If the counter is reset during on-the-fly marking operation, READY OUT (Y5) turns off momentary and there is a case
that the next marking could not be executed due to Warning E751.
• If any of the following operations are executed while the trigger processing operations of multiple triggers are running,
on-the-fly marking is terminated after finishing the running marking, and subsequent triggers will be canceled.
• Closing the shutter
• Sending MKM command with "command reception permission ON"
• Changing the file
• Changing the marking characters by code reader linkage function
114
ON (Open)
OFF (Close)
T1
ON
OFF
ON
T2
OFF
ON
OFF
ON
OFF
ON
OFF
Remarks
Time for marking data creation. It varies depending on the quantity of the setting data.
Keep the ON status for 2ms or more.
Time from when TRIGGER IN (X5) is turned on till when the work piece comes to the
preset marking position
The total time of lasing time and preparing time for next marking is needed for the input
interval of TRIGGER IN.
If this interval is too short, warning E618 occurs and subsequent marking will be canceled.
This is the output to notify that the marking trigger processing completed normally. This is
One-shot output. Set the output time on System settings screen. There is a small margin of
error for the setting value.
ME-LPRF-SM-11
T4
*1
T2
T2
T3
T3
T4
T5
T3
T5
T5