Panasonic LP-RF Series Setup & Maintenance Manual page 173

Laser marker
Hide thumbs Also See for LP-RF Series:
Table of Contents

Advertisement

3.
Establish an online connection between your PC and the laser marking system. Go to the "Maintenance" screen.
4.
Click "Laser pumping" in the ribbon to turn on the laser pumping.
5.
Click "Laser radiation for measurement" in the ribbon.
6.
Enter the laser power and other laser settings, then click
"Laser radiation".
Click "Yes" in the laser radiation confirmation dialog to
irradiate the laser.
• Use the guide laser to confirm the setting position of the power meter
detector. Place the detector so that the cross indication is on the center of
the detector.
• For stable measurement results, it is recommended to obtain the average
output value by measuring the output after about 30 seconds from the start
of laser radiation for 10 to 30 seconds.
• The settings of laser radiation for measurement are common in all files.
WARNING
7.
Click "Stop" to stop laser radiation.
The laser radiation for measurement will automatically
stop after about one minute even without clicking "Stop".
• Be sure to wear protective goggles.
• During the radiation, the laser energy is concentrated to one point. Use due
caution with long period radiation, it may cause a fire or damage to the object.
ME-LPRF-SM-11
"Laser pumping" tool
ON status
OFF status
"Laser radiation for
measurement" tool
173