Registered Characters/External Offset Marking - Panasonic LP-RF Series Setup & Maintenance Manual

Laser marker
Hide thumbs Also See for LP-RF Series:
Table of Contents

Advertisement

4-6-16 Registered characters/external offset marking

SELECT 0 - 2 IN
(No.19-21)
D0 - D15 IN (No.3-18)
SET IN (No.2)
TRIGGER IN (X5)
DATA WAIT OUT (No.38)
SET OK OUT (No.28)
READY OUT (Y5)
PROCESSING OUT (Y10)
Item
Time
T1
0.5ms or more
T2
0ms or more
T3
2 to 510ms
T4
T5
2ms or more
T6
0ms or more
T7
*1 : To specify the registered characters/external offset data number, set SELECT 0 IN to SELECT 2 IN as follows.
SELECT 0 IN (No.19): ON, SELECT 1 IN (No.20): OFF, SELECT 2 IN (No.21): OFF
*2 : Specify the data number of registered characters/external offset by using D0 IN to D15 IN. Refer to "4-3 Signals and
Details of I/O Connector" (P.91).
• SET IN (No.2) for the registered characters/external offset is acceptable when the laser pumping is completed, and the
internal shutter opens.
• If you have configured the registered characters/external offset function, READY OUT (Y5) will not be output until the
data number and SET IN (No.2) are input.
• Enter the data number input and SET IN (No.2) every time for each marking trigger even there is no change to the
marking data.
• Close the shutter if you want to reset the data number after turning on SET IN (No.2).
• READY OUT (Y5) will be output even when specified the data number without any settings.
122
ON
*1
OFF
ON
*2
Data A
OFF
T1
ON
T6
T2
OFF
ON
OFF
ON
OFF
ON
T3
OFF
ON
T4
OFF
ON
OFF
Remarks
After a lapse of 0.5ms or more from specifying SELECT 0 IN to SELECT 2 IN and D0 IN to
D15 IN, turn on SET IN (No.2).
Keep the input until SET OK OUT (No.28) turns on.
One-shot output. Set the output time on the system settings screen. There is a small
margin of error for the setting value.
Time for data creation. It varies depending on the quantity of the setting data.
Keep the ON status for 2ms or more.
Input SET IN (No.2) after DATA WAIT OUT (No.38) turns ON.
• When the next marking data compiling has finished within the trigger processing time:
1ms or less
• When the next marking data compiling did not finish within the trigger processing time:
The remaining time of the marking data compiling (T4)
Data B
T1
T1
T6
T2
T5
T3
T4
Data A
ME-LPRF-SM-11
Data C
T6
T2
T5
T3
Data B
Data C
T7
T5