Termination Procedure - Panasonic LP-RF Series Setup & Maintenance Manual

Laser marker
Hide thumbs Also See for LP-RF Series:
Table of Contents

Advertisement

3-2-2 Termination procedure

1.
Turn OFF the laser pumping.
• PC configuration software control: Click "Laser pumping" on the
ribbon to turn off the laser pumping.
• Remote control: Turn off the laser pumping by LASER SUPPLY
IN (X6) of I/O terminal or by the laser pumping command (LSR).
2.
Overwrite the data as needed.
Click "Save" on the ribbon and select "To laser marking system" or "To PC".
If turning off the power of the laser marker without saving the file under dealing, the data
being edited is deleted. Be sure to check the file saving before turning off the power.
3.
Disconnect the online connection.
Refer to "3-3-4 How to disconnect online connection" (P.69).
• Do not turn the laser marker power OFF while being connected to online. When the power gets turned OFF during data
communication, it may cause the data to corrupt or system failure.
4.
Exit from the Laser Marker NAVI smart.
Select "X" in the upper right corner of the screen.
Alternatively, go to the "Startup" screen and select "Exit" from the menu.
5.
Turn OFF the key switch of the controller and remove the system key.
Please have the safety manager store the system key properly.