Panasonic LP-RF Series Setup & Maintenance Manual page 52

Laser marker
Hide thumbs Also See for LP-RF Series:
Table of Contents

Advertisement

4.
Connect the three wires to the terminals.
The signs of "L (black)", "N (white)" and "PE (GND) (yellow/green)"
show in the cables. Connect each cable to the appropriate terminal.
Screw size: M4
Tightening torque: 1.2N·m
• For the AC power supply cable, use the specified optional AC power
cable or a cable with the enough rating capacity to fulfil the power voltage
specification of this product.
• Please select a cable compliant with the standards in the country or region where it is used.
5.
Attach the resin cover to the terminal.
6.
Fix the AC power cable with the clamp.
Screw size: M4 hex screw
Tightening torque: 1.0N·m
7.
Fix the cover with 2 screws.
The AC power cable should be passed through the cable take-out hole.
Screw size: M3
Tightening torque: 0.5N·m
8.
Make sure that the cables and connectors other than the power supply are connected and then connect the AC power
cable to the AC power supply.
Power voltage: 180V to 264V AC (including ±10% voltage fluctuations)
• The earth terminal of the AC power cable must be permanently grounded.
• Set each connecting cable away from the device that generates high voltage, power line, and large switching surge as
far as possible. If there may be any noise effect on the power supply, use the noise cut-off transformer.
52
ME-LPRF-SM-11
N
Terminal
Resin cover
L
N
PE

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Lp-rf200p

Table of Contents