Panasonic LP-RF Series Setup & Maintenance Manual page 89

Laser marker
Hide thumbs Also See for LP-RF Series:
Table of Contents

Advertisement

No.
Name and description
Y16
INTERLOCK 1 MONITOR: Interlock 1 monitoring
Y17
INTERLOCK 1 MONITOR COM.: Interlock 1 monitoring common
Y18
INTERLOCK 2 MONITOR: Interlock 2 monitoring
Y19
INTERLOCK 2 MONITOR COM.: Interlock 2 monitoring common
INTERLOCK 1 MONITOR (Y16 - Y17) monitors the contact status of INTERLOCK 1 (X16 - X17). INTERLOCK
2 MONITOR (Y18 - Y19) monitors the contact status of INTERLOCK 2 (X18 - X19). For details, refer to "4-4-3
Interlock terminal rating and I/O circuit" (P.100).
State of INTERLOCK terminals
X16 - X17: OPEN
X16 - X17: CLOSE (Short-circuited)
X18 - X19: OPEN
X18 - X19: CLOSE (Short-circuited)
Interlock monitor is switched open and closed with a delay of approx. 50ms with reference to each interlock
input as shown below.
INTERLOCK MONITOR - INTERLOCK MONITOR COM.
Y20
LASER SUPPLY OUT
Output ON during LASER SUPPLY IN (X6) is ON including the preparing time of the laser pumping.
To show the on/off state of the laser supply by using the external warning light or other indicator, connect this
terminal to them.
• Use LASER STANDBY OUT (Y6) for the confirmation of laser pumping completion.
*1 : Set the output time of the one-shot output on the system settings screen of Laser Marker NAVI smart. The setting
range is 2 to 510ms. The initial setting value is 40ms. One-shot output time has a small margin of error for the setting
value.
Operation of INTERLOCK MONITOR terminals
INTERLOCK(+) - INTERLOCK(-)
(X16 - X17, X18 - X19)
(Y16 - Y17, Y18 - Y19)
ME-LPRF-SM-11
Y16 - Y17: CLOSE
Y16 - Y17: OPEN
Y18 - Y19: CLOSE
Y18 - Y19: OPEN
CLOSE
OPEN
50ms
CLOSE
OPEN
50ms
89