No.
Name and description
Count-up value correction (SELECT 1 IN: ON)
w
Count-down value correction (SELECT 0 IN, SELECT 1 IN: ON)
e
Input this number when you change the next marking value of the counter function. The counter value
is specified by the step times of count-up or count-down. The step value indicates a value to increase or
decrease per one counting-up or counting-down.
Specify the count-up/count-down with SELECT 0 IN to SELECT 2 IN.
Specify the target counter number and step times as D0 to D15 and turn ON SET IN (No.2).
• How to select the counter number:
Select a value from D0 to D7 for the counter number to correct the count-up/count-down value.
The counter No. 0 to 3 is assigned at D0 to D3 and the common counter No. 16 to 19 is assigned at D4
to D7 respectively.
In case two or more counter numbers are specified, counter values of all the specified counter numbers
are changed.
• How to specify the step times:
Specify a value in D8 to D15 for the step times of count-up or count-down in the binary system. Indicate
values in the binary system as ON/OFF of D8 to D15 with D8 being the lowest digit value.
Example: Count up or count down the counter of the counter number 3 by two steps
• Turn ON D3 which represents the counter number 3.
• Select "0000 0010", which represents the step times 2 in a 8-bit binary system, by specifying ON/OFF
of D8 to D15 as shown in the below table.
D0 to D7: Counter No. 0 to 3, 16 to 19
Terminal
D0
D1
D2
D3
D4
D5
D6
D7
Counter No. 16 to 19 are the common counters you can use with all the files.
Counter No. to reset (SELECT 2 IN: ON)
r
Input this number when you restore the present counter value to the initial value for files with the counter
function applied.
Specify the target counter number as D0 to D15 and turn ON SET IN (No.2).
• How to select the counter number:
Select the counter number to reset from D0 to D15.
The following counter numbers are assigned to D0 to D15 respectively.
D0 to D3: Counter No. 0 to 3
D4 to D7: Common Counter No. 16 to 19
D8 to D11: Counter No. 4 to 7
D12 to D15: Common Counter No. 20 to 23
In case two or more counter numbers are specified, all counters specified are reset.
Example: When the counter No. 0 to 3 are reset.
Turn ON D0, D1, D2, and D3 which represent the counter No. 0, 1, 2, and 3.
D0 to D7: Counter No. 0 to 3, 16 to 19
Terminal
D0
D1
D2
D3
D4
D5
D6
D7
Counter Nos. 16 to 23 are the common counters you can use with all the files.
Counter No.
Input
0
OFF
1
OFF
2
OFF
3
ON
16
OFF
17
OFF
18
OFF
19
OFF
Counter No.
Input
0
ON
1
ON
2
ON
3
ON
16
OFF
17
OFF
18
OFF
19
OFF
ME-LPRF-SM-11
D8 to D15: Step times
Terminal
Step times (binary)
D8
D9
D10
D11
D12
D13
D14
D15
D8 to D15: Counter No. 4 to 7, 20 to 23
Terminal
Counter No.
D8
4
D9
5
D10
6
D11
7
D12
20
D13
21
D14
22
D15
23
Input
0
OFF
1
ON
0
OFF
0
OFF
0
OFF
0
OFF
0
OFF
0
OFF
Input
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
93