„ I/O connector output signal operation
• The ON/OFF listed in this section refers to the ON/OFF operations. It does not refer to the voltage level (High/Low).
No.
Name and description
27
OUT COM. 2: Output common 2
The common terminal for each output of the I/O connector.
For NPN connection, this terminal is connected to the "- (minus)" side of power which is used for control. For
PNP connection, this terminal is connected to the "+ (plus)" side of power which is used for control.
• IN COM. 1, OUT COM. 1 of the I/O terminal block and IN COM. 2, OUT COM. 2 of the I/O connector are
independent.
If you use the I/O connector terminal, connect input common/output common of the I/O terminal block and
the I/O connector to power supply respectively.
• For details on the connection, refer to "4-5-2 Connecting common terminals" (P.102).
28
SET OK OUT: Setting completion output
The output turns ON when the setting has completed for SET IN (No.2).
Output ON when number inputs such as file No. and counter reset are set. This is one-shot output. *1
• SET OK OUT is a response to SET IN (No.2). To verify if the laser marker has entered into the marking
ready state (trigger input acceptance state), check by READY OUT (Y5).
29
DATE GAP OUT: Date gap output
This terminal turns ON when the date of the system clock has changed (passed the midnight) while TIME
HOLD IN (No.22) is ON.
This is the output to notify you that the laser marker is marking the different date from that of the system clock
while TIME HOLD IN is turned ON.
30
COUNT END A OUT: Counter end A output
31
COUNT END B OUT: Counter end B output
32
COUNT END C OUT: Counter end C output
33
COUNT END D OUT: Counter end D output
Each output turns ON when the count value of the specified counter numbers has marked the end value.
Assign the counter No. to COUNT END A OUT to COUNT END D OUT in system settings of Laser Marker
NAVI smart.
The counter end output remains turned ON with the shutter open until the next marking trigger is input. When
you close the shutter, the counter end output turns OFF.
• As the default setting, counter No. 0 to 3 are assigned to COUNT END A OUT to COUNT END D OUT
respectively.
• The counter value will not be updated at test marking.
• It starts counting from the initial value again once the counter reaches to the end value.
• The counter end output is disabled when "counter update per step" is configured at Step & repeat.
• The counter end output is available when you set the functional character of the counter in a string of the
objects such as character or barcode.