Panasonic LP-RF Series Setup & Maintenance Manual page 208

Laser marker
Hide thumbs Also See for LP-RF Series:
Table of Contents

Advertisement

ERROR
CODE
No response from the image checker. Trigger
E625
processing terminated abnormally.
Settings mismatch between image checker
E626
and laser marking system. Trigger processing
terminated abnormally.
The link control between the laser marker and
image checker has failed.
E627
No settings for code or character checking
available.
Code reading failed when the code reading
E628
function is used for the link control with external
devices.
E629
File switching by code reader has failed.
TRIGGER IN turned off before the minimum
E630
number of scans was reached.
Lasing stopped because the maximum number
E631
of scans was reached.
208
Description
ME-LPRF-SM-11
Measures *1
• Check the connecting status of the laser marking
system and image checker.
• Check if the reading process of the image checker
was successful.
• If you use PV230/PV200, set the total judgement.
• Check the settings of application, type number, and
checker number.
• Check the conformity of the Ethernet settings
with the General communication of PV230/PV200
protocol.
• Verify "Object number to check" in file settings,
and confirm if the number is the same with
the object number you set in barcode/2D code
settings or character settings.
• For the code checking, confirm the code type and
settings of barcode/2D code object in the marking
data are consistent with the settings of the code
reader.
• For the character checking, check if the character
type and number of characters in the marking data
are supported by the image checker.
• Check the status of external devices.
• Improve the marking quality of the code.
• To send the marking strings or to switch the files
by using code reader, confirm the followings:
• Confirm no unavailable characters are in the
code data.
• When using the data extraction function,
confirm the data length in the code data
matches the extraction settings.
• When you do not use the data extraction
function, set the code data less than 299
digits.
• Confirm the specified file number or name exactly
corresponded to the settings in the laser marker.
• To switch the file by the number, specify the
number always with 4-digits in the code data.
• If no settings in the specified file, set the marking
data and save that file to the laser marker.
• Confirm the on/off control of the TRIGGER IN on
the I/O terminal.
• If TRIGGER IN turns on/off properly, change the
setting value of Minimum number of scans of
Trigger mode in File settings.
• Confirm the on/off control of the TRIGGER IN on
the I/O terminal.
• If TRIGGER IN turns on/off properly, change the
setting value of Maximum number of scans of
Trigger mode in File settings.

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Lp-rf200p

Table of Contents