Panasonic LP-RF Series Setup & Maintenance Manual page 143

Laser marker
Hide thumbs Also See for LP-RF Series:
Table of Contents

Advertisement

„ Details of TIMING IN signal
TIMING IN signal: Use
TIMING IN signal is used when the laser marker operation trigger and image checker/code reader operation trigger is input
separately, e.g. when the camera (code reader) field of view is away from the laser marker marking position.
For image checking before marking
Camera etc.
q
TRIGGER IN
Start work location detection (initial operation)
q
Start marking
w
• To control the linkage operation by TIMING IN signal, input TIMING IN signal within 60 seconds after completion of the
initial operation.
• For input of TIMING IN signal, refer to "6-1-9 Timing chart" (P.149).
• Input TIMING IN signal by I/O control. Any communication command cannot input TIMING IN.
TIMING IN signal: Not use
TIMING IN signal is not necessary when the series of operations of the laser marker and the image checker/code reader by
one trigger, e.g. when the camera (code reader) field of view and the laser marker marking position are the same.
For image checking before marking
Camera etc.
Start work location detection and start marking
q
after completion of location detection
Laser marker
w
TIMING IN
Laser marker
q
TRIGGER IN
ME-LPRF-SM-11
For image checking after marking
Laser marker
q
TRIGGER IN
Start marking (initial operation)
q
Start image checking
w
For image checking after marking
Laser marker
q
TRIGGER IN
Start marking and after completion of marking,
q
start image checking
Camera etc.
w
TIMING IN
Camera etc.
143