Reference temperature
Reference electrical angle
Overview of important parameters (refer to the List Manual)
● p0340 Automatic calculation of motor/control parameters
● p0573 Disable automatic calculation of reference values
● p2000 Reference speed reference frequency
● p2001 Reference voltage
● p2002 Reference current
● p2003 Reference torque
● r2004 Reference power
● p2005 Reference angle
● p2007 Reference acceleration
6.3

Modular machine concept

Description
The modular machine concept is based on a maximum target topology created offline in
STARTER. The maximum design of a particular machine type is referred to as the maximum
configuration in which all the machine components that may be used are pre-configured in
the target topology. Sections of the maximum configuration can be removed by
deactivating/removing drive objects (p0105 = 2).
If a component fails, the sub-topology can also be used to allow a machine to continue
running until the spare part is available. In this case, however, no BICO sources must be
interconnected from this drive object to other drive objects.
Example of a sub-topology
The starting point is a machine created offline in STARTER for which "Drive 1" has not yet
been implemented.
● Drive object "Drive 1" must be removed from the target topology via p0105 = 2 in offline
● The DRIVE-CLiQ cable is reconnected from the Control Unit directly to "Drive 2".
● Download the project by choosing "Load to drive object".
● Copy from RAM to ROM.
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
Scaling parameter
100% = 100°C
100 % = 90°
mode.
Default at initial commissioning
-
-
Basic functions
6.3 Modular machine concept
183