Properties of the simple ramp function generator
Figure 2-9
● RFG ramp-up time Tup p1120[DDS]
● RFG ramp-down time Tdn p1121[DDS]
● OFF3 deceleration ramp
● Set ramp function generator
● Freezing of the ramp function generator using p1141 (not in jog mode r0046.31 = 0)
Properties of the extended ramp function generator
Figure 2-10
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
Ramp-up and ramp-down with the simple ramp function generator
– OFF3 ramp-down time p1135[DDS]
– Ramp function generator setting value p1144[CDS]
– Set ramp function generator signal p1143[CDS]
Extended ramp function generator
Extended setpoint channel
2.9 Ramp-function generator