Fixed values for interconnection using BICO technology
The following connector outputs are available for interconnecting any fixed value settings:
● p2900[0...n] CO: Fixed value_%_1
● p2901[0...n] CO: Fixed value_%_2
● p2930[0...n] CO: Fixed value_M_1
Example:
These parameters can be used to interconnect the scaling factor for the main setpoint or to
interconnect an additional torque.
12.4.7

Scaling

Signals for the analog outputs
Table 12-5
List of signals for analog outputs
Signal
Speed setpoint before the setpoint
filter
Speed actual value motor encoder
Actual speed
Drive output frequency
Absolute current actual value
Actual DC link voltage value
Total torque setpoint
Actual active power
Control deviation
Modulation depth
Current setpoint, torque-generating
Current actual value, torque-
generating
Flux setpoint
Flux actual value
Speed controller
PI torque output
Speed controller
I torque output
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
Parameter
r0060
r0061
r0063
r0066
r0068
r0070
r0079
r0082
r0064
r0074
r0077
r0078
r0083
r0084
r1480
r1482
Basic information about the drive system
12.4 BICO technology: interconnecting signals
Unit
RPM
p2000
RPM
p2000
RPM
p2000
Hz
Reference frequency
Aeff
p2002
V
p2001
Nm
p2003
kW
r2004
RPM
p2000
%
Reference control factor
A
p2002
A
p2002
%
Reference flux
%
Reference flux
Nm
p2003
Nm
p2003
Normalization
(100 % = ...)
483