Switching off the controller with the OFF1 signal is delayed by the time entered in p3490.
This allows the attached drives to be braked in a controlled manner. Before the infeed is
switched off, the drives connected to the DC link should be in pulse inhibit mode.
Control and status messages
Table 1-2
Active Infeed open-loop control
Signal name
ON/OFF1
OFF2
Enable operation
Disable motor
operation
Inhibit regenerating
Acknowledge error
Master ctrl by PLC
Table 1-3
Active Infeed status message
Signal name
Ready to power up
Ready to run
Operation enabled
Fault active
No OFF2 active
Power-on disable
Alarm present
Master ctrl by PLC
Pre-charging completed
Line contactor energized feedback
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
Internal control word
STWAE.0
STWAE.1
STWAE.3
STWAE.5
STWAE.6
STWAE.7
STWAE.10
Internal status
word
ZSWAE.0
ZSWAE.1
ZSWAE.2
ZSWAE.3
ZSWAE.4
ZSWAE.6
ZSWAE.7
ZSWAE.9
ZSWAE.11
ZSWAE.12
Binector input
p0840 ON/OFF1
p0844 1 OFF2 and
p0845 2 OFF2
p0852 Enable
operation
p3532 Disable motor
operation
p3533 Inhibit
regenerating
p2103 1 Acknowledge
or p2104
2 Acknowledge or
p2105 3 Acknowledge
p0854 Master ctrl by
PLC
Parameter
r0899.0
r0899.1
r0899.2
r2139.3
r0899.4
r0899.6
r2139.7
r0899.9
r0899.11
r0899.12
Display of internal
control word
r0898.0
A_STW1.0
r0898.1
r0898.3
r0898.5
r0898.6
r2138.7
r0898.10
PROFIdrive telegram 370
A_ZSW1.0
A_ZSW1.1
A_ZSW1.2
A_ZSW1.3
A_ZSW1.4
A_ZSW1.6
A_ZSW1.7
A_ZSW1.9
A_ZSW1.11
A_ZSW1.12
Infeed
1.1 Active Infeed
PROFIdrive telegram
370
A_STW1.1
A_STW1.3
A_STW1.5
A_STW1.6
A_STW1.7
A_STW1.10
29