Bit
Meaning
1
Ready to run
2
Operation enabled
3
Fault active
4
No OFF2 active
5
Reserved
6
Power-on disable
7
Alarm present
8
Reserved
9
Control requested
10
Reserved
11
Bypass energized
12
Line contactor activated
13...
Reserved
15
PosZSW
See function diagram [3645]
Table 10-16 Description of PosZSW (status word, positioning mode)
Bit
Meaning
0
Tracking mode active
1
Speed limiting active
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
10.1 Communications according to PROFIdrive
Comments
1
Ready to run
DC link pre-charged, pulses inhibited
0
Not ready
1
Operation enabled
Vdc = Vdc_setp
0
Operation inhibited
1
Fault active
0
No fault
1
No OFF2 active
0
OFF2 active
1
Power-on disable
Fault active
0
No power-up inhibit
1
Alarm present
0
No alarm
1
Control required
The PLC is requested to assume control. Condition
for applications with isochronous mode: drive
synchronized with PLC system.
0
Local operation
Control only possible on device
1
Bypass energized
Pre-charging is complete and the bypass relay for
the pre-charging resistors is energized.
0
Bypass not energized
Pre-charging not yet complete.
1
Line contactor activated
0
Line contactor not energized
Comments
1
Tracking mode active
0
Tracking mode not active
1
Active
0
Not active
Communication PROFIBUS DP/PROFINET IO
BICO
BO: r0899.1
BO: r0899.2
BO: r2139.3
BO: r0899.4
BO: r0899.6
BO: r2139.7
BO: r0899.9
BO: r0899.11
BO: r0899.12
BICO
BO: r2683.0
BO: r2683.1
373