7.4 Extended brake control
speed controller is immediately enabled - the speed setpoint is enabled after the brake
opening time (p1216). When the master switch is in the zero position, the speed setpoint is
inhibited - the drive is ramp-down using the ramp function generator. The brake closes once
the standstill limit (p1226) has been fallen below. After the brake closing time (p1217), the
speed controller is inhibited (the motor is no longer generating any force). The extended
brake control is used with the modifications described below.
<1>
r1229.3
<1>
[
]
<1>
Figure 7-4
Example, operating brake for a crane drive
7.4.5

Integration

The extended brake control function is integrated in the system as follows.
Function diagrams (see SINAMICS S List Manual)
● 2704 Zero speed detection (r0108.14 = 1)
● 2707 Releasing/applying brake (r0108.14 = 1)
● 2711 Signal outputs (r0108.14 = 1)
Overview of key parameters (see SINAMICS S List Manual)
● r0108.14 Extended brake control
● r0899 CO/BO: Status word sequence control