Servo control
3.6 Current controller
Closed-loop current control
No settings are required for operating the current controller. Optimization measures can be
taken in certain circumstances.
Current and torque limitation
The current and torque limitations are initialized when the system is commissioned for the
first time and should be adjusted according to the application.
Current controller adaptation
The P gain of the current controller can be reduced (depending on the current) by means of
current controller adaptation. Current controller adaptation can be deactivated with the
setting p1402.2 = 0.
Figure 3-11
Flux controller (for induction motor)
The parameters for the flux controller are initialized when the system is commissioned for the
first time and do not usually need to be adjusted.
Commissioning with STARTER
In the STARTER commissioning tool, the "Current controller" parameter screen is selected
with the
Function diagrams (see SINAMICS S List Manual)
● 5710 Current setpoint filters
● 5714 Iq and Id controller
● 5718 Interface to the Motor Module (gating signals, current actual values)
● 5722 Specified field current, flux controller
76
Current controller adaptation
icon in the toolbar:
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
Drive Functions