Function diagrams (see SINAMICS S List Manual)
● 9104 Analog inputs (AI 0 and AI 1)
● 9566 Analog input 0 (AI 0)
● 9568 Analog input 1 (AI 1)
● 9663 Analog input (AI 0)
12.5.4

Analog outputs

Figure 12-13 Analog outputs: Signal processing using AO 0 of TB30/TM31 as an example
Properties
● Adjustable absolute-value generation
● Inversion via binector input
● Adjustable smoothing
● Adjustable transfer characteristic
● Output signal can be displayed via visualization parameter
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
NOTICE
Parameters p4057 to p4060 of the scaling do not limit the voltage values/current values
(for TM31, the input can be used as current input).
Basic information about the drive system