Basic information about the drive system
12.10 Rules for wiring with DRIVE-CLiQ
Rules for FW2.4
● The Voltage Sensing Module (VSM) must be connected to a dedicated DRIVE-CLiQ port
● If possible, the CUA31 should be connected at the end of the line.
Table 12-19 Maximum number of drives that can be controlled by a Control Unit 320
Number of
components
Notes on the maximum number of drives that can be controlled by a CU320:
1) If a CUA31 is connected as the first module to the Control Unit, then the maximum number is
decreased by one.
512
of the Control Unit.
Servo
1 Active Line Module +
6 Motor Modules 1)
Servo and vector V/f:
1 Active Line Module + 5 Motor Modules
(servo: Current controller 125 µs / speed controller
125 µs
Vector V/f:
sampling time of current controller 250 µs / speed
controller 1000 µs
with max. 2 V/f drives
sampling time of current controller 400 µs / speed
controller 1600 µs with more than 2 V/f drives)
In addition, the "Safe Standstill" function can be activated and a TM31 connected.
No function modules must be activated.
Vector V/f (=vector
without speed control
function module and
without encoder)
1 Active Line Module +
4 Motor Modules
1)
(sampling time of current
controller 250 µs / speed
controller 1000 µs)
1 Active Line Module +
6 Motor Modules
)
1
(sampling time of current
controller 400 µs / speed
controller 1600 µs)
1 Active Line Module +
8 Motor Modules
1)
(sampling time of current
controller 500 µs / speed
controller 4000 µs)
1)
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
Vector
1 Active Line Module +
2 Motor Modules
)
1
(sampling time of current
controller 250 µs / speed
controller 1000 µs)
1 Active Line Module +
4 Motor Modules
)
1
(sampling time of current
controller 400 µs / speed
controller 1600 µs)
Drive Functions