Maintenance 5. Joint #1
5.1.4 Joint #1 - Replacing the Electromagnetic Brake
Electromagnetic brake (Joints #1, #2)
Maintenance
J1 brake positioning jig *
Parts
Wire tie (AB100)
Hexagonal wrench
(width across flats: 3 mm)
Tools
Cross-point screwdriver (#2)
Torque wrench
* The belt tensile jig and J1 brake positioning jig are assembly jigs. Use these jigs in relevant maintenance
steps.
The brake is mounted on each joint to prevent the arm from lowering due to its own weight while the Controller
power is OFF or the motor is OFF status. The brake does not work during replacement. Be careful when
performing maintenance work.
170
(M/C Cable Backward)
Name
Qty.
1
2172926
1
1675081
1
1675753
1
For M4 hexagon socket head cap bolt
1
For cross recessed head screws
1
For tightening torque control
Note