Motion Range Setting By Mechanical Stops; Motion Range Setting Of Joint #1 - Epson C12 Series Manipulator Manual

6-axis robots
Hide thumbs Also See for C12 Series:
Table of Contents

Advertisement

Setup & Operation 5. Motion Range

5.2 Motion Range Setting by Mechanical Stops

Using the adjustable mechanical stops physically limits the absolute area that the
Manipulator can move.
Be sure to turn OFF the Manipulator in advance.
Use bolts conforming to the specified length and surface processing (ex:
high corrosion resistance.
Specify the pulse range again after changing the position of the mechanical stop.
For details on the pulse range setting, refer to the Setup & Operation 5.1 Motion Range
Setting by Pulse Range (for All Arms).
Be sure to set the pulse range not to exceed the setting angles of the mechanical stop.

5.2.1 Motion Range Setting of Joint #1

Install the adjustable mechanical stop (J1) to the threaded hole corresponding to the angle
you want to set.
Normally the mechanical stop is not installed.
Angle (
Pulse (pulse)
Adjustable mechanical stop (J1)
54
Hexagon socket head cap bolt M12×30×2 bolts
Tightening torque
a
)
°
42.0 ± 2.1N·m (428 ± 21 kgf·cm)
b
c
a
−145, +110
−9507650
+7212700
Applied
nickel plating
b
c
−110, +145
±240
−7212700
±15736800
+9507650
Not applied
Applied
(standard)
C12 Rev.3
) with

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C12-a1401 seriesC12xl

Table of Contents