Mitsubishi Electric MELSEC Q Series User Manual page 178

Programmabale web server module
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

4 SET-UP AND PROCEDURE BEFORE OPERATION
4 - 54
(d)
Other station specification
Set whether other station is specified or not. For details on accessible
routes, refer to Appendix 2 (2).
1)
No specification
Select this setting when making access to the host CPU.
2)
Other station (Single network)
To access a CPU on another station in the following network
configuration, select a single network.
 Using any one of the following networks
 CC-Link IE Controller Network
 MELSECNET/10
 MELSECNET/H
 CC-Link
 Ethernet
 C24
 CC-Link IE Field Network
(Example)
Accessing a CPU on another station over CC-Link IE Field Network
only
 Using multiple kinds of networks listed in the following
 CC-Link IE Controller Network
 MELSECNET/10
 MELSECNET/H
 Ethernet
 CC-Link IE Field Network
(Example)
Accessing a CPU on another station from MELSECNET/H over CC-
Link IE Field Network
3)
Other station (Different network)
To access a CPU on another station over two kinds of networks
selected from 1) and 2) below, select a different network.
No.
C24
1)
CC-Link
CC-Link IE Controller Network
MELSECNET/10
2)
MELSECNET/H
Ethernet
CC-Link IE Field Network
(Example)
 Accessing a CPU on another station from MELSECNET/H over
CC-Link (2)  1))
 Accessing a CPU on another station from C24 over CC-Link IE
Controller Network (1)  2))
MELSEC-Q
Description
4 - 54

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec qj71ws96