Mitsubishi Electric MELSEC Q Series User Manual page 78

Programmabale web server module
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

3 SPECIFICATIONS
Address
(Decimal
Application
(Hex))
70
(46
)
H
71 to 72
(47
to 48
)
H
H
73 to 74
(49
to 4A
)
H
H
75 to 76
(4B
to 4C
)
H
H
System setting
77 to 78
status area
(4D
to 4E
)
H
H
79 to 80
(4F
to 50
)
H
H
81
(51
)
H
82
(52
)
H
83
(53
)
H
84
System setting
(54
)
H
status area
( 2)
85
(55
)
H
86
(56
)
H
87 to 89
Use prohibited System area
(57
to 59
)
H
H
90
(5A
)
H
91
(5B
)
Dial-up setting
H
status area
92
(5C
)
H
93
(5D
)
H
94 to 97
Use prohibited System area
(5E
to 61
)
H
H
98
(62
)
H
99
(63
)
H
100 to 132
Dial-up setting
(64
to 84
)
status area
H
H
133
(85
)
H
134
(86
)
H
135 to 139
Use prohibited System area
(87
to 8B
)
H
H
3 - 22
IP address setting
0: "Obtain an IP address automatically."
1: "Use the following IP address."
IP address setting: IP address
IP address setting: Subnet mask
IP address setting: Default gateway
DNS server setting: DNS server address 1
DNS server setting: DNS server address 2
Web server setting
0 to 1023
: "Use the default HTTP port number (80)."
1024 to 65535
: "Use the following HTTP port number."
Network type setting
0: "Connecting through LAN or the router."
1: "Dial-up to the network (modem, ADSL)."
Automatic network connection setting at start-up
0: "No connection to network at start-up."
1: "Automatic connection to network at start-up."
FTP server setting
0 to 1023
: "Use the default FTP port number (21)."
1024 to 65535 : "Use the following FTP port number."
Web server setting Register the HTTP port number to NAT of the
router.
0: Not register
1: Register
FTP server setting Register the FTP port number to NAT of the router.
0: Not register
1: Register
Dial method
0: Tone
1: Pulse
Retry: Number of retries.
Retry: Change access point automatically.
0: None
1: Provided
Modem attribute: Communication speed (Unit: bps)
Modem attribute: Call timeout (Unit: Second)
Modem attribute: Dial pause time (Unit: Second)
Modem attribute: Addition set
Addition AT command string
Modem attribute: CALL function
0: None
1: Provided
Modem attribute: Disconnect function, Disconnect time (Unit: Minute)
Name
MELSEC-Q
(From the preceding page)
Read/
Reference
Initial value
write 1
section
0
R
C0A80303
R
H
FFFFFF00
R
H
0
R
0
R
0
R
Section
0
R
4.6.3
0
R
0
R
0
R
0
R
0
R
0
R
0
R
Section
4.6.4
0
R
0
R
0
R
0
R
Section
0
R
4.6.4
0
R
0
R
(Continued on the next page)
3 - 22

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec qj71ws96

Table of Contents