Toshiba H1 Series Data Book page 344

32bit micro controller tlcs-900/h1 series
Table of Contents

Advertisement

(3) Data format
The data format is fixed as follows:
• Data length:
• Parity bits:
• Stop bits:
(4) SFR
Figure 3.14.21 shows the control register SIRCR. Set the data SIRCR during SIO0
is stopping. The following example describes how to set this register:
1) SIO setting
2) LD (SIRCR), 07H
3) LD (SIRCR), 37H
4) Start transmission
and receiving for SIO0
8-bit
none
1bit
; Set the SIO to UART Mode.
; Set the receive data pulse width to 16×.
; TXEN, RXEN Enable the Transmission and receiving.
; The modem operates as follows:
SIO0 starts transmitting.
IR receiver starts receiving.
92CZ26A-341
TMP92CZ26A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tlcs-900Tmp92cz26axbg

Table of Contents