Toshiba H1 Series Data Book page 542

32bit micro controller tlcs-900/h1 series
Table of Contents

Advertisement

When LCDCTL0<FRMON>=1 and LCDCTL0<DLS>=1, frame output is inverted at
intervals set in LCDDVM0<FML3:0> and the LFR signal is inverted at intervals of
"LCP0 × M". The "M" value is specified in LCDDVM0<FMP7:4>.
When <DLS>="1" LFR signal synchronous with front edge of LHSYNC signal.
So, prohibit to set <FREDGE>=1, always need to set <FREDGE>=0.
LVSYNC
LHSYNC
LHSYNC (Expansion)
LCP0
LFR
<FREDGE>=0
<FRMON> = 1
<FMP7:0> = N
<FML7:0> = M
<DLS> = 1
Note
N
M
M
prohibit to set <FREDGE>=1, always need to set <FREDGE>=0.
92CZ26A-539
TMP92CZ26A

Advertisement