2.13.10 Use of volume button

Options:
Deactivated: No volume button is enabled. No additional parameters available.
Activated: The volume button is enabled. The following supplementary parameter is
available:
Object type volume button:
Options:
The parameter is used to specify the size of the communication object for sending
telegrams.
2 x 1 bit: Commands of a volume button are sent with 2 x 1 bit (0 or 1). The following
supplementary parameters are available:
Value for increase:
Options:
The parameter is used to send the command for "Increase volume" with "0" or "1".
Value for decrease:
Options:
The parameter is used to send the command for "Decrease volume" with "0" or "1".
1 x 4 bit: Commands of a volume button are sent with 4 bit. No additional parameters
available.
-
1-byte value [0 - 255]: The value of a volume button is sent as 1-byte value without a
sign. The following supplementary parameters are available:
Change of volume [%]:
Options:
The parameter is used to specify in which step widths the volume is raised or lowered.
Telegram is repeated every [sec.]:
Options:
The parameter is used to specify the space of time between two telegrams.
 
Product manual 2CKA001473B5023
Control elements and application parameter
Deactivated
Activated
2 x 1 Bit
1 x 4 Bit
1-byte value [0 - 100%]
0
1
0
1
Setting option from 1 - 50
Setting option from 0.25 - 1.25 seconds
Control element "Audio control"
│113