Fig. 57. Wiring Across Shipping Splits, (A) Fs 1 And (B) Fs 2 - ABB ACS5000 User Manual

Water-cooled (generation 2)
Hide thumbs Also See for ACS5000:
Table of Contents

Advertisement

A
PCU×1
Key:
(1)
Shipping split
(2)
Cable ducts on each side of the
shipping split
(3)
Connection point
(4)
Charging cable behind water
pipe (not illustrated)

Fig. 57. Wiring across shipping splits, (A) FS 1 and (B) FS 2

PRODUCT
ACS5000W gen. 2
B
3
Explanation
PCUx1 – PCUx1
For auxiliary power supply cables, optical fibers, and signal cables
For charging cable
Laid on the brackets and connected to the busbar
DOCUMENT KIND
User manual
1
PCU×1
2
4
DOCUMENT ID.
3BHS799208 E01
ELECTRICAL INSTALLATION
REV.
LANG.
PAGE
J
en
92/186