10.4. Removing the CDP control panel
When the CDP control panel must be removed from its mounting cradle, follow the
instructions below.
1. When the panel is removed while the drive is in operation, check the setting of parameter
31.01 PANEL LOSS SUPERVISION first.
If the parameter is set to NOT USED , the panel can be removed without interrupting drive
operation.
For more information on parameter settings, see "Appendix G – Signal and
parameter table".
2. To remove the panel, proceed as illustrated.
IMPORTANT! If you remove the CDP control panel during operation, you can only stop the
drive by pressing the emergency-off push button.
The green LED (1) signals that the control voltage has been switched on.
10.4.1. Communication with AMC circuit board
The CDP control panel (1) is connected to the AMC circuit board (2) via an RS485 interface.
1