8.8. Starting the drive

DANGER
Hazardous voltages! Accidental contact with energized components can cause
serious injury or DEATH. All doors and openings must be secured before operation.
→ Remove all foreign objects from the drive
→ Secure and fasten all covers.
→ Close all doors.
→ Lock the doors of the medium voltage compartments.
→ Verify that the release dials of the safety switches are in the locked position.
CAUTION
Cooling system starts automatically! The cooling system can start automatically
after the auxiliary voltage has been switched on.
When you start the drive system locally for the first time after commissioning, have the
following documents at hand:
→ "Appendix D – Wiring diagrams" to identify the circuit breakers to be switched on
→ "Appendix A – Additional manuals", manual of the water cooling unit to check that
the water cooling unit is ready for operation
→ Chapter 9, "CDP control panel", page 138 for information on functions and features
of the CDP control panel