6.8.3.2. Optical fiber cables

NOTICE
Risk of equipment failure! Handle optical fibers with care. A damaged or incorrectly installed
optical fiber cable can degrade data transmission and cause equipment failure.
→ Only use the designated encoder cable conduit that passes through the drive to the EXU; the
conduit extends 10 to 20 mm from the entry plate of the drive.
→ BEFORE you pull the cable through the conduit, cover the cable end with a cap.
→ DO NOT exceed the maximum tensile load of 1.0 N and the minimum bend radius of 25 mm.
→ When you tighten the cable ties DO NOT deform the optical fibers and DO NOT use a cable
tie gun.
→ Hold the connector when you connect or disconnect an optical fiber.
6.8.3.3. Routing optical fiber cables in an EXU cabinet with an ED5V, EB5R,
EB5S, EB7P, and EB7Q type DCS880/DCT880 converter
1. Remove the acrylic protection cover in the cabinet.
2. Unplug the DCS880/DCT880 control panel.
2
1
3
Fig. 79. DCS880/DCT880 H4 converter (ED5V, EB5R, EB5S, EB7P and EB7Q types)
3. Insert a flat-blade screwdriver into one of the indentations at the bottom of the
DCS880/DCT880 front cover.
4. Gently press down the latch tab with the tip of the screwdriver and pull the corner of the
cover forward and repeat for the other side.
5. Slide the removable cover up and then remove the cover.
6. Connect the two optical fibers to the receptacles of slot 1 according to the terminal
numbers printed on the marker sleeves.
PRODUCT
ACS5000W gen. 2
Key:
(1)
DCS880/DCT880 control panel
(2)
Removable front cover
(3)
Indentation
3