NOTE – To prevent accidental switching from remote control to local control, see
Section 9.2.5.2, "Disabling / enabling local lock function", page 155.

9.3. Operational commands

For instructions on how to start and stop the drive system from the CDP control panel, see
Section 8.8, "Starting the drive", page 129 and Section 8.9, "Stopping the drive", page 132.

9.3.1. Setting the direction of rotation

Setting the direction of rotation from the CDP control panel is possible in:
Local control mode (L)
Remote control mode (R)
The arrow on the display indicates the direction of rotation:
When the motor is running, the arrow indicates the actual direction.
When the motor is not running, the arrow indicates the preselected direction.
To set the direction of rotation, press the forward or backward key.
I
0
If you change the direction while the motor is running, the motor automatically ramps down to
zero speed and re-accelerates in the opposite direction to the preset speed. The arrow changes
at zero speed.

9.3.2. Entering a reference value

Entering a reference value from the CDP control panel is possible in:
Local control mode (L)
Remote control mode (R)
PRODUCT
ACS5000W gen. 2
1 L ->
600.0 rpm
StateINU
ReadyRun
MOTOR SP
600.00 rpm
POWER
75.0 kW
1 L <-
600.0 rpm
StateINU
ReadyRun
MOTOR SP
600.00 rpm
POWER
75.0 kW