Hitachi F-ZTAT H8/3039 Series Hardware Manual page 268

Single-chip microcomputer
Table of Contents

Advertisement

• Complementary PWM mode
The buffer register value is transferred to the general register when TCNT3 and TCNT4
change counting direction. This occurs at the following two times:
 When TCNT3 matches GRA3
 When TCNT4 underflows
• Reset-synchronized PWM mode
The buffer register value is transferred to the general register at compare match A3.
Sample Buffering Setup Procedure: Figure 8-48 shows a sample buffering setup procedure.
Buffering
Select general register functions
Set buffer bits
Start counters
Buffered operation
258
1
2
3
Figure 8-48 Buffering Setup Procedure (Example)
1.
Set TIOR to select the output compare or input
capture function of the general registers.
2.
Set bits BFA3, BFA4, BFB3, and BFB4 in TFCR
to select buffering of the required general registers.
3.
Set the STR bits to 1 in TSTR to start the timer
counters.

Advertisement

Table of Contents
loading

This manual is also suitable for:

F-ztat h8/3039F-ztat h8/3038F-ztat h8/3037F-ztat h8/3036

Table of Contents