3.7 Setting Network Diagnostics Parameters

Correct settings on the ports used for diagnostics enable you to use a network diagnostics tool
to diagnose your TE30 using the ports.
Procedure
Step 1 Choose Advanced Settings > Settings > Network > Diagnostics. Set the network
diagnostics parameters by referring to
Table 3-7 Network diagnostics parameters
Parameter
Network
diagnostics
H.323 call
port
RAS source
port
RAS
destination
port
SIP call port
Test network
after exiting
conference
Step 2 Select Save.
----End
Issue 01 (2013-03-27)
Table
Description
Specifies whether to enable the H.323
call port, RAS ports, and SIP call port to
be used for network diagnostics. If you
select this parameter, you must also set
H.323 call port, RAS source port, RAS
destination port, and SIP call port.
Specifies the port the network
diagnostics tool uses to receive and send
call signaling during communication
with your TE30.
Specifies the port your TE30 uses to
receive and send RAS signaling during
communication with the network
diagnostics tool.
Specifies the port the network
diagnostics tool uses to receive and send
RAS signaling during communication
with your TE30.
Specifies the port your TE30 uses to
send SIP signaling during
communication with the network
diagnostics tool.
Specifies whether to perform the ping
operation after your TE30 exits a
conference. Ping results are recorded in a
log.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3-7.y
Setting
This parameter is deselected by
default.
The default value is 1820.
The default value is 1819.
The default value is 1819.
The default value is 5160.
The default value is Enable.