The Management Blade
Ê Press the reset button (2), to reboot the management blade.
Ê Insert the management blade again (see
On the HyperTerminal screen the upgrade menu will be displayed as shown in
figure below:
SuperI/O.......OK
SRAM...........OK
Flash..........OK
NIC............OK
Boot Code Rev
0.05I
Hi, You are in Download Mode
(1) Upgrade Firmware from Serial Port
(2) Upgrade Firmware from Network
(3) Network Parameters
-------------------------------------
Choose: _
Ê Enter 1 to upgrade the firmware via the serial port.
Ê Close the HyperTerminal session.
Ê Execute the batch job update.bat in the folder containing the files all.bin and
uplod.exe.
The status of the firmware upgrade process is displayed on a console window
as shown in figure below.
When the console window has closed, the upgrade process has finished.
02
BX600
124
Removal and Installation Routines
page
02-BX600-115).
March 2006
U41057-J21-Z146-1-76