172 Program features
Parameter
1002 EXT2 COMMANDS
1102 EXT1/EXT2 SEL
1106 REF2 SELECT
1201 CONST SPEED SEL
1401 RELAY OUTPUT 1
1601 RUN ENABLE
1805 DO SIGNAL
2102 STOP FUNCTION
2201 ACC/DEC 1/2 SEL
2202 ACCELER TIME 1
2203 DECELER TIME 1
2205 ACCELER TIME 2
2206 DECELER TIME 2
2207 RAMP SHAPE 2
3201 SUPERV 1 PARAM
3202 SUPERV 1 LIM LO
3203 SUPERV 1 LIM HI
8401 SEQ PROG ENABLE EXT2
8402 SEQ PROG START
8404 SEQ PROG RESET
8406 SEQ LOGIC VAL 1
8407 SEQ LOGIC OPER 1 AND
8408 SEQ LOGIC VAL 2
8415 CYCLE CNT LOC
8416 CYCLE CNT RST
Setting
Additional information
SEQ PROG
Start, stop, direction commands for EXT2
EXT2
EXT2 activation
AI1+SEQ
Sequence programming output as REF2
PROG
NOT SEL
Deactivation of constant speeds
SEQ PROG
Relay output RO 1 control as defined by
parameter 8423/.../8493
NOT SEL
Deactivation of Run enable
SEQ PROG
Digital output DO control as defined by
parameter 8423/.../8493
RAMP
Ramp stop
SEQ PROG
Ramp as defined by parameter 8422/.../8452.
1 s
Acceleration/deceleration ramp pair 1
0 s
20 s
Acceleration/deceleration ramp pair 2
20 s
5 s
Shape of the acceleration/deceleration ramp 2
171
Sequence counter (signal
CNTR) supervision
30
Supervision low limit
30
Supervision high limit
Sequence programming enabled
DI1
Sequence programming activation through
digital input (DI1)
DI1(INV)
Sequence programming reset (ie reset to
state 1, when DI1 signal is lost (1 -> 0)
DI4
Logic value 1
Operation between logic value 1 and 2
DI5
Logic value 2
ST5 TO NEXT
Sequence counter activation, ie sequence
count increases every time the state changes
from state 5 to state 6.
STATE 1
Sequence counter reset during state transition
to state 1
0171 SEQ CYCLE