ABB ACS355 User Manual page 236

Hide thumbs Also See for ACS355:
Table of Contents

Advertisement

236 Actual signals and parameters
All parameters
No.
Name/Value
2610 USER
DEFINED U1
0...120% of U
N
2611 USER
DEFINED F1
0.0...500.0 Hz
2612 USER
DEFINED U2
0...120% of U
N
2613 USER
DEFINED F2
0.0...500.0 Hz
2614 USER
DEFINED U3
0...120% of U
N
2615 USER
DEFINED F3
0.0...500.0 Hz
2616 USER
DEFINED U4
0...120% of U
N
2617 USER
DEFINED F4
0.0...500.0 Hz
2618 FW VOLTAGE
0...120% of U
N
2619 DC
STABILIZER
DISABLE
ENABLE
Description
Defines the first voltage point of the custom U/f curve at the
frequency defined by parameter
See section
Custom U/f ratio
V Voltage
Defines the first frequency point of the custom U/f curve.
Frequency
Defines the second voltage point of the custom U/f curve at
the frequency defined by parameter
F2. See section
Custom U/f ratio
V Voltage
Defines the second frequency point of the custom U/f curve. 20.0 Hz
Frequency
Defines the third voltage point of the custom U/f curve at the
frequency defined by parameter
See section
Custom U/f ratio
V Voltage
Defines the third frequency point of the custom U/f curve.
Frequency
Defines the fourth voltage point of the custom U/f curve at
the frequency defined by parameter
F4. See section
Custom U/f ratio
V Voltage
Defines the fourth frequency point of the custom U/f curve.
Frequency
Defines the voltage of the U/f curve when frequency is equal
to or exceeds the motor nominal frequency
NOM
FREQ). See section
V Voltage
Enables or disables the DC voltage stabilizer. The DC
stabilizer is used to prevent possible voltage oscillations in
the drive DC bus caused by motor load or weak supply
network. In case of voltage variation, the drive tunes the
frequency reference to stabilize the DC bus voltage and
therefore the load torque oscillation.
Disabled
Enabled
2611 USER DEFINED
on page 141.
2613 USER DEFINED
on page 141.
2615 USER DEFINED
on page 141.
2617 USER DEFINED
on page 141.
(9907 MOTOR
Custom U/f ratio
on page 141.
Def/FbEq
19% of
F1.
U
N
1 = 1 V
10.0 Hz
1 = 0.1 Hz
38% of
U
N
1 = 1 V
1 = 0.1 Hz
47.5% of
F3.
U
N
1 = 1 V
25.0 Hz
1 = 0.1 Hz
76% of
U
N
1 = 1 V
40.0 Hz
1 = 0.1 Hz
95% of
U
N
1 = 1 V