Type designation key

The type designation contains information on the specifications and configuration of
the drive. You find the type designation on the type designation label attached to the
drive. The first digits from the left express the basic configuration, for example
ACS355-03E-09A7-4. The optional selections are given after that, separated by +
signs, for example +J404. The explanations of the type designation selections are
described below.
ACS355 product series
1-phase/3-phase
01 = 1-phase input
03 = 3-phase input
Configuration
E = EMC filter connected, 50 Hz frequency
U = EMC filter disconnected, 60 Hz frequency
Output current rating
In format xxAy, where xx indicates the integer part and y the fractional part,
eg 09A7 means 9.7 A.
For more information, see section
Input voltage range
2 = 200...240 V AC
4 = 380...480 V AC
Options
B063 = IP66/IP67/UL Type 4x enclosure
(product variant)
J400 = ACS-CP-A assistant control panel
J404 = ACS-CP-C basic control panel
J402 = MPOT-01 potentiometer
K451 = FDNA-01 DeviceNet
K454 = FPBA-01 PROFIBUS DP
K457 = FCAN-01 CANopen
K458 = FMBA-01 Modbus RTU
K466 = FENA-01 EtherNet/IP / Modbus TCP/IP
K452 = FLON-01 LonWorks
1) The ACS355 is compatible with panels that have the following panel revisions and panel
firmware versions. To find out the revision and firmware version of your panel, see page 74.
Panel type
Basic control panel
Assistant control panel
Assistant control panel (Asia)
Note that unlike the other panels, the ACS-CP-D is ordered with a separate material code.
Operation principle and hardware description 29
Ratings
on page 358.
K469 = FECA-01 EtherCAT
H376 = Cable gland kit (IP66/IP67/UL Type 4x)
1)
F278 = Input switch kit
1)
C169 = Pressure compensation valve
Extension modules
G406 = MPOW-01 auxiliary power module
L502 = MTAC-01 pulse encoder module
L511 = MREL-01 relay output module
Type code
ACS-CP-C
ACS-CP-A
ACS-CP-D
ACS355-03E-09A7-4+J404+...
Panel revision
M or later
F or later
Q or later
Panel firmware
version
1.13 or later
2.04 or later
2.04 or later

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents