Fieldbus Equivalent; Default Values With Different Macros - ABB ACS355 User Manual

Hide thumbs Also See for ACS355:
Table of Contents

Advertisement

176 Actual signals and parameters

Fieldbus equivalent

Example: If
2017 MAX TORQUE 1
system, an integer value of 1000 corresponds to 100.0%. All the read and sent values
are limited to 16 bits (-32768...32767).

Default values with different macros

When application macro is changed (parameter
updates the parameter values to their default values. The table below shows the
parameter default values for different macros. For other parameters, the default
values are the same for all macros (shown in the parameter list starting on page 185).
Index Name/
ABB
Selection
STANDARD
9902 APPLIC
1 =
MACRO
ABB
STANDARD
1001 EXT1
2 =
COMMANDS
1002 EXT2
0 =
COMMANDS
SEL
1003 DIRECTION
3 =
REQUEST
1102 EXT1/EXT2
0 =
SEL
1103 REF1 SELECT
1 =
1106 REF2 SELECT
2 =
1201 CONST
9 =
SPEED SEL
1304 MINIMUM AI2
1.0%
1501 AO1
103
CONTENT SEL
1601 RUN ENABLE
0 =
SEL
2201 ACC/DEC 1/2
5 =
SEL
3201 SUPERV 1
103
PARAM
3401 SIGNAL1
103
PARAM
9904 MOTOR CTRL
3 =
MODE
SCALAR:
FREQ
Note: It is possible to control several functions with one input (DI or AI), and there is a
chance of mismatch between these functions. In some cases it is desired to control
several functions with one input.
For example in the ABB standard macro, DI3 and DI4 are set to control constant
speeds. On the other hand, it is possible to select value 6 (DI3U,4D) for parameter
(see page 217) is set from an external control
3-WIRE
ALTERNA
TE
2 =
3 =
3-WIRE
ALTERNAT
E
DI1,2
4 =
9 =
DI1P,2P,3
NOT
0 =
NOT
0 =
SEL
SEL
3 =
3 =
REQUEST
REQUEST
EXT1
0 =
EXT1
0 =
AI1
1 =
AI1
1 =
AI2
2 =
AI2
2 =
DI3,4
10 =
DI4,5
9 =
1.0%
1.0%
102
102
NOT
0 =
NOT
0 =
SEL
SEL
DI5
0 =
NOT
5 =
SEL
102
102
102
102
1 =
1 =
VECTOR:
VECTOR:
SPEED
SPEED
9902 APPLIC
MOTOR
HAND/
POT
AUTO
4 =
5 =
MOTOR
HAND/AUT
POT
O
DI1F,2R
2 =
DI1,2
2 =
NOT
0 =
NOT
21 =
SEL
3 =
3 =
REQUEST
REQUEST
EXT1
0 =
EXT1
3 =
AI1
12 =
1 =
DI3U,4D(N
C)
AI2
2 =
AI2
2 =
DI3,4
5 =
DI5
0 =
SEL
1.0%
20.0%
102
102
NOT
0 =
NOT
0 =
SEL
SEL
DI5
0 =
NOT
0 =
SEL
SEL
102
102
102
102
1 =
1 =
VECTOR:
VECTOR:
SPEED
SPEED
MACRO), the software
PID
TORQUE
CONTROL
CONTROL
6 =
7 =
PID
TORQUE
CONTROL
CTRL
DI1,2
1 =
DI1
2 =
DI5,4
20 =
DI5
2 =
1 =
3 =
FORWARD
REQUEST
DI3
2 =
DI2
3 =
AI1
1 =
AI1
1 =
AI2
19 =
2 =
PID1OUT
NOT
3 =
DI3
4 =
20.0%
20.0%
102
102
NOT
4 =
DI4
0 =
SEL
NOT
0 =
NOT
5 =
SEL
102
102
102
102
1 =
2 =
VECTOR:
VECTOR:
SPEED
TORQ
DI1,2
DI1,2
DI3
AI1
AI2
DI4
NOT
DI5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents