S
6
S
ECTION
YSTEM
6.1
2-26
R
EQUIREMENTS AND
Cabling
This section provides cabling requirements and specifications for various
equipment used in the SV9100 system.
Figure 2-3 Connecting the DLC Using Twisted 2-Pair Cable
chassis connected with each of the multiline terminals and single line telephones
by a separate twisted 1-pair cable or 2-pair cable (only for multiline terminals).
Figure 2-3 Connecting the DLC Using Twisted 2-Pair Cable
DLC
Refer to the following tables for cabling requirements and specifications.
Table 2-16 DT300/DT400 Series Loop Resistance and Cable Length on
page 2-26
Table 2-17 DT700/DT800 Series Loop Resistance and Cable Length on
page 2-27
Table 2-18 Cable Connection Between Analog Port and Single Line
Equipment on page 2-28
Table 2-19 Cabling Requirements on page 2-29
Table 2-16 DT300/DT400 Series Loop Resistance and Cable Length
Terminal or Adapter
DTL-2E-1 (BK) TEL
DTL-6DE-1 (BK) TEL
DTL-12E-1 (BK) TEL
DTL-8LD-1 (BK) TEL
DTL-8LD-1 (WH) TEL
DTL-12BT-1 (BK) TEL
DTL-12PA-1 (BK) TEL
DTL-12D-1 (BK) TEL
DTL-12D-1 (WH) TEL
S
PECIFICATIONS
Twisted 2-Pair Cable
By Twisted 1-Pair Cable
(without AC Adapter)
24 AWG
1,969 ft (600m)
1,969 ft (600m)
1,969 ft (600m)
1,969 ft (600m)
1,969 ft (600m)
1,969 ft (600m)
1,969 ft (600m)
Issue 3.0
is a diagram of the
RJ-11
Multiline Terminal
SV9100 System Specifications