6-18
3.1.3
Manual Registration
If you are registering more than one repeater to the same base, you must
use the manual registration procedure.
1.
Connect the repeater to power for 1~5 seconds and then disconnect
it.
2.
Reconnect the power to the repeater. The LED on the repeater
flashes slowly, indicating the repeater is in registration mode.
The repeater stays in registration mode for five minutes. If you
cannot complete the registration in five minutes, repeat the
procedure starting with step 1.
3.
Set the base in registration mode. (Consult the owner's manual that
came with your base station for more information.)
4.
The LED on the front of the repeater flashes quickly, with no
interruptions.
If the LED has brief interruptions in the flash, you need to reset
your telephone system PIN to 0000. (Refer to
Telephone System PIN on page
5.
Press the handset TALK? key to go off-hook. The LED stops flashing.
6.
Use the number pad on the handset to assign a repeater number.
Press a number between 2 and 7. Each repeater number can be
used only once per base. (These numbers are independent of any
handset extension number.)
7.
When the repeater accepts the assignment, the LED flashes a
corresponding number of times.
8.
Press the STAR? key to confirm the registration, and then the END?
key. The LED goes off for two seconds, flashes for a brief moment,
and then remains on steady.
The repeater is now registered to this base station. You can repeat the
procedure with each repeater that you want to register to this base, or you
can disconnect the power and move the repeater to the selected
location.Registration for a Daisy-Chain Layout
CAUTION
Registering the repeaters to operate in a daisy-chain or sequential layout
requires network administrator access and configuration software. Contact
your installer or refer to the DTL-RPT-1 Administrator's Guide (provided with
the configuration software) for more information.
The repeater remains registered even if you disconnect the AC
adapter or there is a power failure. If you want to clear the
registration (for example, so you can register to a different
base), you must reset the repeater.
Issue 3.0