Issue 3.0
SV9100 System Hardware Manual
7.
Connect the two-conductor station cable from the CN5 connectors in the
PGD(2)-U10 ADP to the external relay/external page.

Figure 9-13 PGD(2)-U10 ADP Cable Connection

TIP
The PGD(2)-U10 ADP provides amplifiers for each page
output port (for a maximum of +8 dBM, 600 ohms at 1KHz).
No additional page amplification is provided by the
PGD(2)-U10 ADP but, if required, an external page amplifier
can be used for additional amplification.
The page output of the GCD-CP10 does not provide
amplification (for a maximum output of -3 dBm, 600 ohms at
1KHz). If the paging volume is not satisfactory using the CN8
or CN9 connector on the GCD-CP10, the PGD(2)-U10 ADP
should be used instead.