9-78
12.2.6.3
Install the 4-Port Digital Logging Unit
1.
Connect the 4-Port Digital Logging Unit device to the USB
cable and plug the USB cable in the PC. Windows responds
with the Found New Hardware wizard.
2.
Insert the provided NEC BackOffice CD in the CD drive of
the PC.
Direct the installation of the driver to Specific Location and
specify the Driver folder on the CD. Windows should find
and load the device driver.
3.
Before inserting the next USB cable, restart the PC. If
Windows responds with Found New Hardware again, direct
to the CD a second time and restart the PC. After you get a
clean restart and Windows recognizes the device on restart,
install the next device.
4.
Leave the CD in the CD drive and connect the next device,
you may need to direct windows to the CD with each device
you connect. Also, you may need to restart the PC with each
device connection (this may require two restarts per device).
5.
After all devices are connected, restart the PC and view the
devices in Device Manager to ensure proper installation.
6.
Connect the telephone wiring to the 4-Port Digital Logging
Unit. Be sure to note which extension is connected to which
port of the devices (each device has a unique serial
number). In the Recorder window you see the serial number
followed by a trailing digit (1~4), this identifies the port on
the device.
TIP
Label each Digital Station Port with the extension it
records. Refer to
Ports.
Before the telephone wiring is connected, the
devices may temporarily show Failed and then
reinitialize. This is normal operation.
Figure 9-36 4-Port Digital Station

Figure 9-61 Digital Station Ports