Mitsubishi Electric M32R Series User Manual page 380

Mitsubishi 32-bit risc single-chip microcomputers
Table of Contents

Advertisement

10
(Continued from the preceding page)
D
Bit Name
9-11
TIO1M
(TIO1 operation mode selection)
12
TIO0ENS (TIO0 enable/
measure input source selection)
13-15
TIO0M
(TIO0 operation mode selection)
Note 3: This register must always be accessed in halfwords.
Note 4: Always make sure the counter has stopped and is idle before setting or changing operation modes.
TIN3
TIN3S
TIN4
TIN4S
TIN5S
TIN5
TIN6
TIN6S
Note: This diagram is shown for the explanation of TIO control registers, and is partly omitted.
Figure 10.4.5 Outline Diagram of TIO0-4 Clock/Enable Inputs
Clock bus
Input event bus
3 2 1 0
3 2 1 0
S
S
S
S
S
S
3 2 1 0
3 2 1 0
S : Selector
10-110
MULTIJUNCTION TIMERS
10.4 TIO (Input/Output-related 16-bit Timer)
Function
000: Single-shot output mode
001: Delayed single-shot output mode
010: Continuous output mode
011: PWM output mode
100: Measure clear input mode
101: Measure free-run input mode
11X: Noise processing input mode
0: No selection
1: External input TIN3
000: Single-shot output mode
001: Delayed single-shot output mode
010: Continuous output mode
011: PWM output mode
100: Measure clear input mode
101: Measure free-run input mode
11X: Noise processing input mode
clk
TIO 0
en/cap
clk
TIO 1
en/cap
clk
TIO 2
en/cap
clk
TIO 3
en/cap
clk
TIO 4
en/cap
R
W
Ver.0.10