Note : When you selected f(BCLK) for the BRG count source (CDVI), you are subject to limitations that
the baud rate register value you set must be equal to or greater than 7.
Figure 12.6.3 Procedure for UART Transmit Initialization
Initial settings for UART
transmission
Set SIO Transmit/Receive Mode Register
Set SIO Transmit Control Register
Set SIO Baud Rate Register
Set SIO Interrupt Related Registers
Set the Interrupt Controller
Set DMAC related registers
Set input/output port
Operation Mode Register
Initial settings for UART
transmission finished
12.6 Transmit Operation in UART Mode
• Set register to UART mode
• Set parity (when enabled,
• Set stop bit length
• Set character length
• Select clock divider's divide-by ratio
• Divide-by ratio H'00 to H'FF (Note)
• Enable/disable transmit interrupt
(When using interrupt)
(When using DMAC)
12-49
SERIAL I/O
select odd/even)
Ver.0.10